What the cold does to a heat pump here
The heat runs nine months a year here, September through May, and the overnight low averages 13°F across December, January and February. About 150 nights a year drop to freezing or below. About 25 of those get down to 0°F or colder.
A standard heat pump starts falling behind well before it hits that kind of cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it typically needs backup heat to make up the difference. The average winter night here is 13°F, below both marks, and every one of the 150 nights at or below freezing is colder than both of them too. In this county, a standard heat pump is running on backup more often than not through the winter.
Cold climate models are a different machine than the one those two numbers describe. To carry the ENERGY STAR Cold Climate label, a heat pump has to deliver at least 1.75 units of heat for every unit of electricity at 5°F, and still hold 70 percent of its 47°F capacity at that same temperature, checked by outside testing. In a field test of prototype cold-climate units running in occupied homes over two winters, backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. If a heat pump goes into this house, it needs to be one of those, not a standard unit.