What winter here does to a heat pump
Your furnace question here is really a cold question. The average overnight low across December, January and February is 18 degrees, and heat runs eight months a year, October through May. A standard heat pump starts losing ground before it even gets that cold. Below 40°F its heat output falls short of what it is rated for, and below about 35°F it typically needs backup heat to make up the difference. At 18 degrees you are well past both marks, and so is every one of the roughly 135 nights a year here that drop to freezing or below.
That does not mean a heat pump cannot heat your house. It means it needs help doing it. Backup heat, usually electric resistance, picks up the gap on the coldest nights. An ENERGY STAR Cold Climate heat pump is built for this: to earn that label it has to keep making real heat, at least 1.75 units out for every one unit of electricity in, down at 5°F, and hold onto most of its capacity at that temperature. A standard model carries no such guarantee. If a heat pump is on the table for your house, which one it is matters as much as whether.
Field testing on cold-climate models backs this up in practice, not just on paper. Over two winters of occupied homes running them, backup heat covered only a small share of the total heat made between 0°F and 35°F, and the system running on backup alone was rare even above 0°F. Nine nights a year here reach that 0°F mark. The other 126 nights at or below freezing are the kind a good cold-climate heat pump is designed to handle on its own.