What winter here actually asks of a heat pump
Your furnace, or whatever replaces it, has real work to do here. Heat runs nine months a year, September through May, and the overnight low averages 15°F across December, January and February. That's not a cold snap. That's the normal Tuesday night.
A standard heat pump starts losing ground before it gets anywhere near 15°F. Below 40°F it puts out less heat than its rating says. Below about 35°F it typically needs backup heat to keep up. Saratoga County drops to freezing or below on about 145 nights a year, over half the nights the heat runs, and every one of those nights is past both marks. Eleven nights a year reach 0°F or below, and at that point a standard heat pump is making only a fraction of its rated heat.
That doesn't rule out a heat pump. It means the backup heat is not a footnote, it's part of the system. A cold-climate model changes the math: to earn that label it has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, checked by outside testing, not the maker's word. In field testing of cold-climate models in real homes over two winters, backup heat covered only a small share of the load between 0°F and 35°F, and the system running on backup alone was rare even above 0°F. A standard heat pump in a Saratoga County house leans on backup heat most winter nights. A cold-climate one mostly doesn't.