What the cold here does to a heat pump
Winter here is long and it gets genuinely cold. The heat runs eight months a year, October through May, and the overnight low averages 20°F across December, January and February. About 140 nights a year drop to freezing or below, more than half the nights the heat is even running. Six nights a year hit 0°F or colder.
A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. Twenty degrees, the average winter low here, is well past both marks. So is every single one of those 140 freezing nights. This is not a machine that spends most of its winter at full strength in this county.
That doesn't mean it quits. A cold climate model, the kind certified under ENERGY STAR's Cold Climate program, has to prove it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature, checked by independent testing. Field tests of prototype cold climate heat pumps in occupied homes back this up: backup heat covered only a small share of the load between 0°F and 35°F, and the system running on backup alone was rare even above 0°F. If a heat pump goes in here, it should be a cold climate unit, not the standard kind the 40°F and 35°F marks describe.
Cooling is the easier call. Summers run three months, June through August, shorter than winter and without the extreme-cold question. A heat pump handles that side the same way an air conditioner does, as one system instead of two.