Cold nights here and what a heat pump does with them
Winter is the main event in Clinton County. Heat runs nine months a year here, September through May, and cooling only shows up in July. Whatever you buy, you're buying it mostly to keep the house warm, not cool.
The overnight low averages 11°F across December, January and February. That's well below the two marks that matter for a standard heat pump: below 40°F it starts putting out less heat than its rating, and below about 35°F it often needs backup heat to make up the difference. At 11°F average, both marks are behind you before the night even gets started. Of the roughly 150 nights a year here that hit freezing or below, every single one is colder than both thresholds.
About 19 nights a year drop to 0°F or below. That's under a quarter of the freezing nights, so it's not the normal case, but it happens most winters. A standard heat pump built to the federal minimum is not built for that stretch, which is why it leans on backup heat when it's running one.
This doesn't rule out a heat pump. ENERGY STAR's Cold Climate models are tested to make real heat at 5°F, at least 1.75 units of heat per unit of electricity, while holding onto most of their 47°F capacity. Field testing on prototype cold-climate units in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. That's a different machine than the one priced in the running-cost figures above, which assumes the federal minimum with nothing added for backup.