What winter here does to a heat pump
Your furnace runs about eight months a year here, October through May, and winter is the thing this decision turns on. The overnight low averages 21°F across December, January and February. That is below the point where a standard heat pump starts to struggle. Below 40°F, a standard heat pump puts out less heat than its rating says. Below about 35°F, it often needs backup heat to make up the difference. Your winter average sits under both marks.
This is not a rare cold snap. About 130 nights a year here fall to freezing or below, more than half the nights across the whole heating season. On all of those nights, a standard heat pump is working below both the 40°F and 35°F marks, not just the occasional night it dips low. Only about 4 nights a year reach 0°F, so the deep cold is rare. The ordinary cold is not.
None of this rules out a heat pump. It means the heat pump that works here has to be built for the cold, not the federal minimum. A unit carrying the ENERGY STAR Cold Climate label has to prove, in third-party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. A field test of prototype cold-climate heat pumps over two winters found backup heat covered only a small share of the heat needed between 0°F and 35°F, and the units rarely ran on backup alone even above 0°F. That is the difference between a heat pump that was built for Orange County winters and one that was not.