What winter here does to a heat pump
Your heat here has to run eight months a year, October through May, and the overnight low averages 18°F across December, January and February. That's not a cold snap, that's the normal night. A standard heat pump falls short of its rated heat output once it's below 40°F outside, and often needs backup heat once it's below about 35°F. Every one of those eight months runs colder than that mark on a good number of nights.
Over half the nights in heating season here, about 155 of roughly 245, drop to freezing or below. That's the range where a standard heat pump is already working past its rating. The good news is how rarely it gets truly extreme: only about 8 nights a year reach 0°F, so the deep cold that pushes a heat pump hardest is the exception here, not the rule.
A heat pump carrying the ENERGY STAR Cold Climate label is built for this. To earn it, a heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, tested by someone other than the manufacturer. That's a different machine than the standard one the 40°F and 35°F marks describe. Field tests of prototype cold-climate heat pumps in occupied homes back this up: backup heat covered only a small share of the heat needed between 0°F and 35°F, and the home running on backup heat alone was rare even above 0°F.
So the question for your house isn't whether a heat pump can work in Chemung County. It's which heat pump. A standard one will lean hard on backup heat for most of an average winter night here. A cold-climate one is built to avoid that.