What the cold does to a heat pump here
Winter here is long and it bites. Heat runs eight months a year, October through May, and the overnight low averages 19°F across December, January and February. About 140 nights a year drop to freezing or below, over half the nights in that eight-month stretch. A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to cover the difference. Both of those marks sit above the 19°F average low here, and every single one of the 140 freezing nights falls below both.
That does not mean a heat pump stops working. Cold-climate models exist for this reason, and ENERGY STAR will only put its Cold Climate label on a unit that still makes at least 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that same temperature, checked by outside testing, not the manufacturer's word. A field test that followed prototype cold-climate heat pumps through two winters in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and the units rarely ran on backup alone unless it was below 0°F. Cayuga County only sees about 8 nights a year that cold. So the question for this house is not whether a heat pump can survive the winter here. A cold-climate one can. The question is what it costs to run it through eight months of weather built for a furnace.