What the cold actually does to a heat pump here
Winter here is long and mostly mild. Heat runs seven months, October through April, and the overnight average in the coldest stretch is 28°F. That number matters because a standard heat pump starts losing ground before it gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. Richmond County's average winter low sits below both marks.
That doesn't mean the cold here is severe. Nights at or below freezing number about 85 a year, and that's under half the nights in the heating season. Only about one night a year drops to 0°F or below, where a heat pump struggles most. So the problem isn't brutal cold. It's that an ordinary night here, 28°F, already falls in the range where a standard heat pump is working below its rating and may be leaning on backup heat to keep the house warm.
A heat pump built to the ENERGY STAR Cold Climate spec is a different machine in this regard. It has to hold onto at least 70 percent of its 47°F heating capacity at 5°F and still produce 1.75 units of heat per unit of electricity at that temperature, verified by outside testing. Field tests of prototype cold-climate units in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. That's the range Richmond County actually lives in. A standard heat pump and a cold-climate one answer this county's winter very differently.