What the cold here does to a heat pump
Winter here averages 17°F overnight, and that number matters more than any spec sheet. A standard heat pump starts losing heating capacity below 40°F and often needs backup heat below about 35°F. Here, every single night that drops to freezing or below, about 145 of them a year, falls under both marks. This isn't a once-a-winter cold snap you can shrug off. It's most of the heating season.
That doesn't mean a heat pump can't heat your house. It means it won't do it alone. Below 35°F it leans on a backup heat source, usually electric resistance coils, to make up the difference. The cost band above already shows a heat pump running higher than a gas furnace, $3.26 against $2.00 per 100,000 Btu, and that number is the best case: it's the federal minimum rating with nothing added for backup heat. Run the backup strip heat on a 17°F night and the real cost climbs past that.
There's a newer category built for this. ENERGY STAR Cold Climate heat pumps are tested to hold at least 70 percent of their rated heat at 5°F, well below what Schenectady sees on all but about 9 nights a year. Field testing on prototype cold-climate units found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. If a heat pump is going into this county, that's the category that makes sense here, not the standard model the $3.26 figure is built on.