What winter here does to a heat pump
A furnace runs about nine months a year here, September through May, and the overnight low averages 17°F through December, January and February. A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F its heat output drops under its rating. Below about 35°F it often needs backup heat to make up the difference. Both marks sit above this county's winter average, not below it.
About 165 nights a year here fall to 32°F or below, over half of the roughly 275 nights across the nine months the heat runs. Every one of those nights is already past both the 40°F and 35°F marks. A heat pump sized for this county spends most of the season working below its rated output.
It is not the deep cold that does the damage, it is how often the milder cold shows up. Only about 12 nights a year reach 0°F or below, a small part of the 165 nights at or below freezing. The season here is mostly nights in the 20s and 30s, not nights near zero, and that is the stretch where a standard heat pump leans hardest on backup heat.
A heat pump built to the ENERGY STAR Cold Climate spec is a different machine on paper. To earn that label it has to produce at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, checked by outside testing. A two-winter field test of prototype cold-climate heat pumps in occupied homes backed that up: backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. If you are looking at a heat pump for this county, that is the spec that decides whether it holds up.